Brief Description
This epoxy resin cast dry-type transformer uses high-quality silicon steel core and copper windings, encapsulated with epoxy resin under vacuum casting. It has no insulating oil, featuring flame retardant, explosion-proof, low partial discharge, low noise and minimal maintenance. Ideal for indoor power distribution, high-rise buildings, hospitals, data centers, subway, photovoltaic and wind power stations. Suitable for environments with strict fire safety & environmental requirements.
Silicon Steel Laminated Core: Low loss cold rolled silicon steel sheet, optimized core structure to reduce noise & no-load loss.
Application Scenarios
2.Hospitals, schools, public facilities
3.Data centers
4.Metro / tunnel projects
5.Solar & wind renewable power plants
6.Industrial workshops
Product Advantages
1. Fire Safety – IEC 60076-11 Class F1
Epoxy resin self-extinguishes instantly. No oil – ideal for hospitals, subways, data centers, and high-rises.
2. Zero Maintenance & Low Operating Cost
No oil checks, pits, or separate rooms required. Lower total cost than oil-immersed units.
3. Energy Efficiency – GB 20052-2024 Grade 1
~30% lower no-load losses vs. SCB12. Operating noise: 45-52 dB(A).
4. Short-Circuit Withstand
Vacuum casting and full-oblique core joints provide up to 8% impedance withstand.
5. Partial Discharge < 5 pC
Vacuum casting eliminates voids, achieving <5 pC PD for decades of reliable insulation.
6. Compact & Environmentally Friendly
30-50% smaller footprint. No contamination risk. Installable at load centers. Fully recyclable.
Production Process
Raw material inspection → HV & LV coil winding → coil curing → core cutting & stacking → coil and insulation assembly →
overall assembly & auxiliary fitting → factory tests → sandblasting and painting → final inspection, marking & packaging.
Technical Specifications – SCB12-800/10 Dry-Type Transformer
| No. | Parameter | Specification |
| 1 | Energy Efficiency Class | SCB12 |
| 2 | Rated Capacity | 800 kVA |
| 3 | Rated Voltage (HV/LV) | 10 kV / 0.4 kV |
| 4 | Rated Current (HV/LV) | 46.19 A / 1154.7 A |
| 5 | Voltage Ratio | 10 ± 2 × 2.5% / 0.4 kV |
| 6 | Short-Circuit Impedance | 6% |
| 7 | Vector Group | Dyn11 |
| 8 | Rated Frequency | 50 Hz |
| 9 | Insulation Class | Class F |
| 10 | Temperature Rise Limit | 100 K |
| 11 | Rated Insulation Level | 35/5 kV |
| 12 | Lightning Impulse Withstand Voltage (HV Side) | 75 kV |
| 13 | Power Frequency Withstand Voltage (HV Side) | 35 kV / 60 s |
| 14 | Power Frequency Withstand Voltage (LV Side) | 5 kV / 60 s |
| 15 | Power Frequency Withstand Voltage (Neutral Point) | 5 kV / 60 s |
| 16 | No-Load Loss | 1.215 kW |
| 17 | Load Loss | 6.96 kW |
| 18 | No-Load Current | 0.70% |
| 19 | Efficiency | ≥99% |
| 20 | Partial Discharge Level | <10 pC |
| 21 | Noise Level | ≤60 dB |
Product Range:
• Epoxy resin cast dry-type transformers (≤35 kV)
• Oil-immersed transformers
• Photovoltaic boost transformers
• YB12 box-type substations
• Intelligent high/low-voltage switchgear
• Prefabricated box transformers for EV charging
• Smart charging piles
• Distributed photovoltaic products
Certificates and Test Reports
Global market case
EV Gigafactory, Shangha
Deployed across renewable energy plants, urban distribution networks, industrial facilities, commercial buildings, and critical infrastructure.
Oil-Immersed Transformers – Indonesia
Export Power Distribution
S13/S20 series oil-immersed distribution transformers supplied for Indonesian grid and industrial networks.
Dry-Type Transformers – Australia
Export Commercial building
SCB14/SCB18 series cast-resin dry-type transformers, 11/22 kV class, supplied to Australian commercial and data-center networks. Fire-safe, maintenance-free, engineered to AS/NZS 60076.
Total Quality Management (TQM)
ISO 9001, ISO 14001, OHSAS 45001 certified. Full-chain quality control from material to delivery.
A. Incoming Quality Control (IQC)
All raw materials undergo full testing before production. Non-conforming materials rejected.
B. In-Process Quality Control (IPQC)
10+ QC inspections: core stacking, excitation, winding resistance, insulation, partial discharge, dimensional checks.
C. Final Quality Control (FQC)
Every unit 100% tested before shipment:
Routine Tests (IEC 60076-11):
• Winding resistance
• Voltage ratio & vector group
• No-load loss & current
• Load loss & short-circuit impedance
• Insulation resistance
• Applied voltage (hi-pot)
• Induced voltage
• Partial discharge (<5 pC)
Type Tests (on request):
• Temperature rise
• Lightning impulse (95 kV)
• Short-circuit withstand
• Acoustic noise
Special Tests:
• Zero-sequence impedance
• No-load current harmonic analysis
D. Certifications
• ISO 9001
• ISO 14001
• ISO 45001
•CE
• IEC 60076
Transportation
Shipping Methods:
• Sea (FCL/LCL) via major Chinese ports: 15-45 days.
• Rail: China-Europe Railway Express: 15-20 days.
• Road: Regional deliveries.
• Air: For urgent small shipments.
Trade Terms:
EXW, FOB, CIF,
Lead Time:
• 30-630 kVA: 20-30 days.
• 800-2,500 kVA: 35-45 days.