This epoxy resin cast dry-type transformer uses high-quality silicon steel core and copper windings, encapsulated with epoxy resin under vacuum casting. It has no insulating oil, featuring flame retardant, explosion-proof, low partial discharge, low noise and minimal maintenance. Ideal for indoor power distribution, high-rise buildings, hospitals, data centers, subway, photovoltaic and wind power stations. Suitable for environments with strict fire safety & environmental requirements.
Silicon Steel Laminated Core: Low loss cold rolled silicon steel sheet, optimized core structure to reduce noise & no-load loss.
Application Scenarios
2.Hospitals, schools, public facilities
3.Data centers
4.Metro / tunnel projects
5.Solar & wind renewable power plants
6.Industrial workshops
Product Advantages
1. Fire Safety – IEC 60076-11 Class F1
Epoxy resin self-extinguishes instantly. No oil – ideal for hospitals, subways, data centers, and high-rises.
2. Zero Maintenance & Low Operating Cost
No oil checks, pits, or separate rooms required. Lower total cost than oil-immersed units.
3. Energy Efficiency – GB 20052-2024 Grade 1
~30% lower no-load losses vs. SCB12. Operating noise: 45-52 dB(A).
4. Short-Circuit Withstand
Vacuum casting and full-oblique core joints provide up to 8% impedance withstand.
5. Partial Discharge < 5 pC
Vacuum casting eliminates voids, achieving <5 pC PD for decades of reliable insulation.
6. Compact & Environmentally Friendly
30-50% smaller footprint. No contamination risk. Installable at load centers. Fully recyclable.
Production Process
Winding Fabrication Low-voltage and high-voltage windings are wound by automatic winding machine; insulation strips are placed between layers.
Winding Curing (Epoxy Casting for Resin Dry Type) Windings are placed in moulds, vacuum poured with epoxy resin and cured at constant temperature.
Winding Demoulding & Finishing Finished windings are demoulded, trimmed and inspected for surface defects.
Core & Winding Assembly The core and high/low voltage windings are assembled together; supporting insulators and connection bars are installed.
Wiring & Accessories Installation Internal wiring, terminal blocks, temperature sensors, fans and enclosure parts are mounted.
Electrical Performance Test Conduct routine tests: resistance measurement, ratio test, insulation resistance, partial discharge, withstand voltage test.
Enclosure Assembly & IP Protection Check Install metal enclosure, check IP protection level as required (e.g. IP54).
Final Inspection & Packing Overall visual and functional recheck; qualified products are cleaned and packed for shipment.
Technical Specifications – SCB12-800/10 Dry-Type Transformer
| No. | Parameter | Specification |
| 1 | Energy Efficiency Class | SCB12 |
| 2 | Rated Capacity | 800 kVA |
| 3 | Rated Voltage (HV/LV) | 10 kV / 0.4 kV |
| 4 | Rated Current (HV/LV) | 46.19 A / 1154.7 A |
| 5 | Voltage Ratio | 10 ± 2 × 2.5% / 0.4 kV |
| 6 | Short-Circuit Impedance | 6% |
| 7 | Vector Group | Dyn11 |
| 8 | Rated Frequency | 50 Hz |
| 9 | Insulation Class | Class F |
| 10 | Temperature Rise Limit | 100 K |
| 11 | Rated Insulation Level | 35/5 kV |
| 12 | Lightning Impulse Withstand Voltage (HV Side) | 75 kV |
| 13 | Power Frequency Withstand Voltage (HV Side) | 35 kV / 60 s |
| 14 | Power Frequency Withstand Voltage (LV Side) | 5 kV / 60 s |
| 15 | Power Frequency Withstand Voltage (Neutral Point) | 5 kV / 60 s |
| 16 | No-Load Loss | 1.215 kW |
| 17 | Load Loss | 6.96 kW |
| 18 | No-Load Current | 0.70% |
| 19 | Efficiency | ≥99% |
| 20 | Partial Discharge Level | <10 pC |
| 21 | Noise Level | ≤60 dB |
Product Range:
• Epoxy resin cast dry-type transformers (≤35 kV)
• Oil-immersed transformers
• Photovoltaic boost transformers
• YB12 box-type substations
• Intelligent high/low-voltage switchgear
• Prefabricated box transformers for EV charging
• Smart charging piles
• Distributed photovoltaic products
Certificates and Test Reports
Our dry type transformers comply with IEC60076 & GB/T10228, with ISO9001, ISO14001, ISO45001 and CE certifications. Complete type test report and IP protection certificate are available. Each unit undergoes strict factory tests before shipment.
Global market case
EV Gigafactory, Shangha
Deployed across renewable energy plants, urban distribution networks, industrial facilities, commercial buildings, and critical infrastructure.
Oil-Immersed Transformers – Indonesia
S13/S20 series oil-immersed distribution transformers supplied for Indonesian grid and industrial networks.
Dry-Type Transformers – Australia
Export Commercial building
SCB14/SCB18 series cast-resin dry-type transformers, 11/22 kV class, supplied to Australian commercial and data-center networks. Fire-safe, maintenance-free, engineered to AS/NZS 60076.
Total Quality Management (TQM)
ISO 9001, ISO 14001, OHSAS 45001 certified. Full-chain quality control from material to delivery.
A. Incoming Quality Control (IQC)
All raw materials undergo full testing before production. Non-conforming materials rejected.
B. In-Process Quality Control (IPQC)
10+ QC inspections: core stacking, excitation, winding resistance, insulation, partial discharge, dimensional checks.
C. Final Quality Control (FQC)
Every unit 100% tested before shipment:
Routine Tests (IEC 60076-11):
• Winding resistance
• Voltage ratio & vector group
• No-load loss & current
• Load loss & short-circuit impedance
• Insulation resistance
• Applied voltage (hi-pot)
• Induced voltage
• Partial discharge (<5 pC)
Type Tests (on request):
• Temperature rise
• Lightning impulse (95 kV)
• Short-circuit withstand
• Acoustic noise
Special Tests:
• Zero-sequence impedance
• No-load current harmonic analysis
D. Certifications
• ISO 9001
• ISO 14001
• ISO 45001
•CE
• IEC 60076
Transportation
Shipping Methods:
• Sea (FCL/LCL) via major Chinese ports: 15-45 days.
• Rail: China-Europe Railway Express: 15-20 days.
• Road: Regional deliveries.
• Air: For urgent small shipments.
Trade Terms:
EXW, FOB, CIF,
Lead Time:
• 30-630 kVA: 20-30 days.
• 800-2,500 kVA: 35-45 days.