Quick Answer
A 630 kVA 33 kV dry-type transformer for a data center is a cast-resin, oil-free, three-phase transformer that steps 33 kV medium voltage down to 400/415 V for UPS and server hall distribution. Data centers specify it because cast resin is self-extinguishing and contains no oil, so no fire suppression bund, oil pit or leakage risk is required indoors. Per IEC 60076-11, partial discharge is limited to 10 pC, and with AN/AF cooling the unit accepts around 40–50% overload during UPS switchover or maintenance.
Product Overview
This is a three-phase indoor dry-type cast resin transformer rated 630 kVA with a primary voltage of 33 kV and a secondary voltage of 415 V (400 V optional). The windings are vacuum-cast in epoxy resin, giving a non-hygroscopic, flame-retardant and maintenance-free insulation system that is safe to install inside the electrical room of a data center, directly at the load centre.
Designed for Tier III / Tier IV data centers, colocation facilities, hyperscale and AI/GPU compute halls, it feeds UPS input, power distribution units and mechanical loads. The unit is manufactured under ISO 9001 and tested in accordance with IEC 60076-11, IEC 60076-1 and EN 50588-1.
Why Data Centers Choose Dry-Type Over Oil-Immersed
| Consideration | Cast Resin Dry Type | Oil-Immersed | Data Center Impact |
| Fire risk | Self-extinguishing, F1 fire behaviour, no oil | Combustible oil, needs bund and suppression | Dry type can sit indoors at the load centre |
| Installation | Indoor, no oil pit | Outdoor or fire-rated room | Saves fire-rated room and bund cost |
| Maintenance | Maintenance-free, no oil testing | Periodic oil sampling and filtration | Lower OPEX over 25 years |
| Humidity | Operates at 100% RH, non-hygroscopic | Moisture ingress risk | Stable during commissioning and outages |
| Cooling | AN with AF fans for 40–50% overload | ONAN | Matches UPS switchover peaks |
| Monitoring | PT100 + PTC + thermostat as standard | Optional | Feeds BMS and DCIM directly |
Our recommendation: for indoor data center electrical rooms, specify cast resin dry type unless the room is fire-rated and the unit is installed outdoors.
Key Features
- Fire-safe and oil-free— epoxy resin cast windings are self-extinguishing and halogen-free, suitable for installation at the load centre without a fire-rated transformer room.
- Low partial discharge— vacuum casting under controlled conditions keeps partial discharge at or below 10 pC (IEC 60076-11), protecting insulation over a 25-year service life.
- Low loss design— high-permeability grain-oriented silicon steel with step-lap core reduces no-load loss and meets EN 50588-1 / EU Ecodesign 2019/1783 Tier 2 requirements.
- AN / AF cooling— natural air cooling at rated load, forced-air fans raise capacity by approximately 40–50% for UPS switchover and N+1 contingency.
- Thermal monitoring as standard— PT100 sensors in each winding phase plus PTC thermistors, with alarm and trip contacts for BMS and DCIM integration.
- Harmonic-capable design— K-factor or K-13 rated design available for UPS, rectifier and GPU server loads with high harmonic content.
- Electrostatic shield option— earthed screen between HV and LV windings attenuates common-mode noise, protecting sensitive IT equipment.
- Low noise— typically below 58 dB(A) at 1 m, suitable for electrical rooms adjacent to occupied areas.
- Moisture and dust resistant— fully encapsulated windings allow operation in 100% relative humidity and coastal or dusty environments.
Typical Applications
- Hyperscale and AI / GPU compute data centers
- Colocation facilities and Tier III / Tier IV server halls
- Edge data centers and modular containerised IT halls
- UPS input and output distribution
- Financial trading and telecom core sites
- Network operations centres and server rooms in commercial buildings
Standards and Certifications
Designed and type-tested in accordance with IEC 60076-11 (dry-type power transformers), IEC 60076-1 (general requirements) and EN 50588-1. Energy performance meets EU Ecodesign Regulation 2019/1783 Tier 2 (EN 50588-1) . Manufactured under ISO 9001, ISO 14001 and ISO 45001. CE available; KEMA or equivalent third-party type test reports available on request.
FAQ:
1.What is the delivery time
Normally in 30 days,if large order more than 100 piece,production time 40 days
2.What is your advantage
Fast delivery,Strict quality control,provide OEM,ODM service of the distribution transformer
3. what is your payment terms
We accept T/’T,L/C at sight,At least 30% deposit when signed contract,70% balance before shipment
4.what is the warranty time
warranty time 2 years
5.Which company is the top 10 best transformer factory in CHINA
Frankly speaking,Shendian electric is not top 10 transformers in CHINA,But we permit to provide top 10 service in Transformer field
6.Why choose shendian
Our mission is to be top brand transformers in global market.We focused on product quality as our life.