{"id":18898,"date":"2026-08-01T14:51:29","date_gmt":"2026-08-01T06:51:29","guid":{"rendered":"https:\/\/www.cnbcsd.com\/?p=18898"},"modified":"2026-09-04T13:08:46","modified_gmt":"2026-09-04T05:08:46","slug":"2500kva-rated-capacity-scb14-dry-type-transformers","status":"publish","type":"post","link":"https:\/\/www.cnbcsd.com\/pt\/2500kva-rated-capacity-scb14-dry-type-transformers\/","title":{"rendered":"Transformadores a seco SCB14 com capacidade nominal de 2500 kVA"},"content":{"rendered":"<p>Serial Number Name Technical Specifications<br \/>\none Basic technical parameters of transformer<br \/>\n1 Energy efficiency rating SCB14<br \/>\n2 Rated capacity (kVA) 2500<br \/>\n3 Rated voltage (kV) High voltage \/ Low voltage 10\/0.4<br \/>\n4 Rated current (A) High voltage \/ Low voltage 144.33\/3608.44<br \/>\n5 Open-circuit voltage ratio (kV) 10\u00b12*2.5%\/0.4<br \/>\n6 Short-circuit impedance (%) U High &#8211; Low 6<br \/>\n7 Linkage group label D,yn11<br \/>\n8 Rated frequency (Hz) 50<br \/>\n9 Insulation class F-class<br \/>\n10 Temperature rise limit 100K<br \/>\n11 Rated insulation level 35\/5<br \/>\n11 High voltage side Peak withstand voltage of lightning impulse (kV) 75<br \/>\n11 High voltage side Short-time power frequency withstand voltage RMS value (kV) 35\/60S<br \/>\n11 Low-pressure side Short-time power frequency withstand voltage RMS value (kV) 5\/60S<br \/>\n11 Neutral point side Short-time power frequency withstand voltage RMS value (kV) 5\/60S<br \/>\n12 loss No-load loss (kW) 2.45<br \/>\n12 loss Load loss (kW) 15.445<br \/>\n13 No-load current (%) 0.60<br \/>\n14 efficiency (%) \u226599%<br \/>\n15 Partial discharge quantity (PC) &lt;10<br \/>\n16 Noise level (dB) \u226465<br \/>\ntwo Terminal blocks<br \/>\n1 Terminal allowable load \/<br \/>\n2 Longitudinal (N) \/<br \/>\n3 Horizontal (N) \/<br \/>\n4 Vertical tension (N) \/<\/p>","protected":false},"excerpt":{"rendered":"<p>Serial Number Name Technical Specifications one Basic technical parameters of transformer 1 Energy efficiency rating SCB14 2 Rated capacity (kVA) 2500 3 Rated voltage (kV) High voltage \/ Low voltage 10\/0.4 4 Rated current (A) High voltage \/ Low voltage 144.33\/3608.44 5 Open-circuit voltage ratio (kV) 10\u00b12*2.5%\/0.4 6 Short-circuit impedance (%) U High &#8211; Low [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":18771,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[137],"tags":[161,181],"class_list":["post-18898","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-dry-type-transformer","tag-dry-type-transformer","tag-transformers"],"_links":{"self":[{"href":"https:\/\/www.cnbcsd.com\/pt\/wp-json\/wp\/v2\/posts\/18898","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.cnbcsd.com\/pt\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.cnbcsd.com\/pt\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.cnbcsd.com\/pt\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.cnbcsd.com\/pt\/wp-json\/wp\/v2\/comments?post=18898"}],"version-history":[{"count":2,"href":"https:\/\/www.cnbcsd.com\/pt\/wp-json\/wp\/v2\/posts\/18898\/revisions"}],"predecessor-version":[{"id":19090,"href":"https:\/\/www.cnbcsd.com\/pt\/wp-json\/wp\/v2\/posts\/18898\/revisions\/19090"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.cnbcsd.com\/pt\/wp-json\/wp\/v2\/media\/18771"}],"wp:attachment":[{"href":"https:\/\/www.cnbcsd.com\/pt\/wp-json\/wp\/v2\/media?parent=18898"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.cnbcsd.com\/pt\/wp-json\/wp\/v2\/categories?post=18898"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.cnbcsd.com\/pt\/wp-json\/wp\/v2\/tags?post=18898"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}