{"id":18602,"date":"2026-07-26T11:10:50","date_gmt":"2026-07-26T03:10:50","guid":{"rendered":"https:\/\/www.cnbcsd.com\/?p=18602"},"modified":"2026-07-27T11:17:06","modified_gmt":"2026-07-27T03:17:06","slug":"hxgn17-12-ac-metal-ring-main-switchgear-load-switch","status":"publish","type":"post","link":"https:\/\/www.cnbcsd.com\/fr\/hxgn17-12-ac-metal-ring-main-switchgear-load-switch\/","title":{"rendered":"HXGN17-12 commutateur principal \u00e0 anneau m\u00e9tallique AC (commutateur de charge)"},"content":{"rendered":"<p><strong>Vue d&#8217;ensemble<\/strong><br \/>\nL&#8217;appareil de commutation HXGN17-12 AC Metal Ring Main Unit (interrupteur de charge) (abr\u00e9g\u00e9 Ring Main Unit) est un nouveau type d&#8217;appareil de commutation haute tension d\u00e9velopp\u00e9 pour r\u00e9pondre aux besoins de la r\u00e9novation et de la construction du r\u00e9seau \u00e9lectrique urbain. Dans les syst\u00e8mes d&#8217;alimentation \u00e9lectrique, il est \u00e9galement utilis\u00e9 pour interrompre les courants de charge et les courants de court-circuit, ainsi que pour fermer les courants de court-circuit. Cette unit\u00e9 principale \u00e0 anneau est \u00e9quip\u00e9e d&#8217;interrupteurs de charge sous vide FZRN25 et FZRN21 avec un m\u00e9canisme \u00e0 ressort qui peut \u00eatre actionn\u00e9 manuellement ou \u00e9lectriquement, les interrupteurs de mise \u00e0 la terre et les couteaux d&#8217;isolation sont \u00e9quip\u00e9s de m\u00e9canismes manuaoperating, Cette unit\u00e9 principale \u00e0 anneau pr\u00e9sente une forte int\u00e9gration du syst\u00e8me, une taille compacte, aucun risque de combustion ou d&#8217;explosion et des fonctions fiables &#8220;five.prevention&#8221;.<br \/>\nCette unit\u00e9 principale \u00e0 anneau est conforme aux dispositions pertinentes des normes GB3906 &#8220;3-35kV AC Metal-Enclosed Switchgear&#8221; et lEc60420 &#8220;High-voltage AC LoadSwitch-Fuse Combination Units&#8221;.<\/p>\n<p><strong>Signification du mod\u00e8le<\/strong><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-18604\" src=\"https:\/\/www.cnbcsd.com\/wp-content\/uploads\/2026\/07\/Model-Meaning-HXGN17-12-scaled.jpg\" alt=\"\" width=\"2560\" height=\"438\" srcset=\"https:\/\/www.cnbcsd.com\/wp-content\/uploads\/2026\/07\/Model-Meaning-HXGN17-12-scaled.jpg 2560w, https:\/\/www.cnbcsd.com\/wp-content\/uploads\/2026\/07\/Model-Meaning-HXGN17-12-768x131.jpg 768w, https:\/\/www.cnbcsd.com\/wp-content\/uploads\/2026\/07\/Model-Meaning-HXGN17-12-1536x263.jpg 1536w, https:\/\/www.cnbcsd.com\/wp-content\/uploads\/2026\/07\/Model-Meaning-HXGN17-12-2048x350.jpg 2048w\" sizes=\"auto, (max-width: 2560px) 100vw, 2560px\" \/><\/p>\n<p><strong>Conditions d&#8217;utilisation<\/strong><br \/>\n\u25aa Temp\u00e9rature de l&#8217;air ambiant: -15&#8217;C \u00e0 +40&#8217;C<br \/>\n\u25aa Altitude : 1 000 m\u00e8tres ou moins;<br \/>\n\u25aa Conditions d&#8217;humidit\u00e9: humidit\u00e9 moyenne de Daly ne d\u00e9passant pas 95%, avec une pression moyenne quotidienne de vapeur d&#8217;eau ne d\u00e9passant pas 2,2 kPa; une humidit\u00e9 moyenne mensuelle ne d\u00e9passant pas 90 %, avec une pression moyenne mensuelle de vapeur d&#8217;eau ne d\u00e9passant pas 1,8 kPa;<br \/>\n\u25aa Intensit\u00e9 du s\u00e9isme: Pas sup\u00e9rieure \u00e0 la magnitude 8;<br \/>\n\u25aa Lieux exempts de gaz corrosifs ou inflammables et d&#8217;autres polluants importants.<br \/>\nRemarque: si les conditions d\u00e9passent les conditions normales de fonctionnement ci-dessus, les utilisateurs peuvent consulter notre soci\u00e9t\u00e9.<\/p>\n<p><strong>Principaux param\u00e8tres techniques<\/strong><\/p>\n<table>\n<tbody>\n<tr class=\"firstRow\">\n<td colspan=\"1\" rowspan=\"1\">Item<\/td>\n<td rowspan=\"1\"><\/td>\n<td>Unit<\/td>\n<td>FKN12-12<\/td>\n<td colspan=\"1\" rowspan=\"1\">FZN25-12<\/td>\n<\/tr>\n<tr>\n<td colspan=\"1\" rowspan=\"1\">Rated voltage<\/td>\n<td rowspan=\"1\"><\/td>\n<td><\/td>\n<td colspan=\"2\" rowspan=\"1\">12<\/td>\n<\/tr>\n<tr>\n<td colspan=\"1\" rowspan=\"1\">1min power frequency withstand voltage<\/td>\n<td rowspan=\"1\"><\/td>\n<td>kV<\/td>\n<td colspan=\"2\" rowspan=\"1\">To the ground and phase 42; lsolation fracture 48<\/td>\n<\/tr>\n<tr>\n<td colspan=\"1\" rowspan=\"1\">Lightning impulse voltage<\/td>\n<td rowspan=\"1\"><\/td>\n<td><\/td>\n<td colspan=\"2\" rowspan=\"1\">To the ground and phase 75; Isolation fracture 85<\/td>\n<\/tr>\n<tr>\n<td colspan=\"1\" rowspan=\"1\">Rated frequency<\/td>\n<td rowspan=\"1\"><\/td>\n<td>Hz<\/td>\n<td colspan=\"2\" rowspan=\"1\">50<\/td>\n<\/tr>\n<tr>\n<td colspan=\"1\" rowspan=\"1\">Rated current of main bus<\/td>\n<td rowspan=\"1\"><\/td>\n<td><\/td>\n<td colspan=\"2\" rowspan=\"1\">630<\/td>\n<\/tr>\n<tr>\n<td colspan=\"1\" rowspan=\"10\">Load switch<\/td>\n<td colspan=\"1\" rowspan=\"1\">Rated current<\/td>\n<td>A<\/td>\n<td colspan=\"2\" rowspan=\"1\">630<\/td>\n<\/tr>\n<tr>\n<td colspan=\"1\">Current life at rated current<\/td>\n<td>\u6b21time<\/td>\n<td colspan=\"2\" rowspan=\"1\">Notless than100<\/td>\n<\/tr>\n<tr>\n<td colspan=\"1\">Disconnect no-load transformer capacity<\/td>\n<td>kVA<\/td>\n<td colspan=\"2\" rowspan=\"1\">1250<\/td>\n<\/tr>\n<tr>\n<td colspan=\"1\">Rated heat stable current<\/td>\n<td>kA\/s<\/td>\n<td colspan=\"2\" rowspan=\"1\">Ground switch 20\/2<\/td>\n<\/tr>\n<tr>\n<td colspan=\"1\">Rated dynamic stable current(peak)<\/td>\n<td><\/td>\n<td colspan=\"2\" rowspan=\"1\">50<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"1\">Rated short circuit closing current(peak)<\/td>\n<td>kA<\/td>\n<td colspan=\"2\" rowspan=\"1\">50<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"1\">Rated current of the fuse<\/td>\n<td>kA<\/td>\n<td colspan=\"2\" rowspan=\"1\">100<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"1\">Rated transfer current<\/td>\n<td>kA<\/td>\n<td>1500<\/td>\n<td colspan=\"1\" rowspan=\"1\">2000<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"1\">Rated short-circuit breaking current<\/td>\n<td><\/td>\n<td colspan=\"2\" rowspan=\"1\">315<\/td>\n<\/tr>\n<tr>\n<td colspan=\"1\" rowspan=\"1\">Fitted with fusemodel<\/td>\n<td colspan=\"1\" rowspan=\"1\"><\/td>\n<td colspan=\"2\" rowspan=\"1\">S\u25a1LAJ-12(XRNT\u25a1-10)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Mechanical life<\/td>\n<td>time<\/td>\n<td>2000<\/td>\n<td colspan=\"1\" rowspan=\"1\">10000<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Auxiliary circuit 1min power frequency voltage<\/td>\n<td>kV<\/td>\n<td>2<\/td>\n<td colspan=\"1\" rowspan=\"1\"><\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Operating voltage of electric actuator<\/td>\n<td>V<\/td>\n<td>Ac DC 220;110<\/td>\n<td colspan=\"1\" rowspan=\"1\"><\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Class of protection<\/td>\n<td><\/td>\n<td>IP2X<\/td>\n<td colspan=\"1\" rowspan=\"1\"><\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Overall dimensions (w\u00d7d\u00d7h)<\/td>\n<td>mm<\/td>\n<td>650(850)\u00d7900\u00d72000(2200)<\/td>\n<td colspan=\"1\" rowspan=\"1\"><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><\/p>","protected":false},"excerpt":{"rendered":"<p>Vue d&#8217;ensemble L&#8217;appareil de commutation HXGN17-12 AC Metal Ring Main Unit (interrupteur de charge) (abr\u00e9g\u00e9 Ring Main Unit) est un nouveau type d&#8217;appareil de commutation haute tension d\u00e9velopp\u00e9 pour r\u00e9pondre aux besoins de la r\u00e9novation et de la construction du r\u00e9seau \u00e9lectrique urbain. Dans les syst\u00e8mes d&#8217;alimentation \u00e9lectrique, il est \u00e9galement utilis\u00e9 pour interrompre les [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":18603,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[136],"tags":[162],"class_list":["post-18602","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-smart-hv-lv-switchgear","tag-smart-hv-lv-switchgear"],"_links":{"self":[{"href":"https:\/\/www.cnbcsd.com\/fr\/wp-json\/wp\/v2\/posts\/18602","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.cnbcsd.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.cnbcsd.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.cnbcsd.com\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.cnbcsd.com\/fr\/wp-json\/wp\/v2\/comments?post=18602"}],"version-history":[{"count":2,"href":"https:\/\/www.cnbcsd.com\/fr\/wp-json\/wp\/v2\/posts\/18602\/revisions"}],"predecessor-version":[{"id":18672,"href":"https:\/\/www.cnbcsd.com\/fr\/wp-json\/wp\/v2\/posts\/18602\/revisions\/18672"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.cnbcsd.com\/fr\/wp-json\/wp\/v2\/media\/18603"}],"wp:attachment":[{"href":"https:\/\/www.cnbcsd.com\/fr\/wp-json\/wp\/v2\/media?parent=18602"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.cnbcsd.com\/fr\/wp-json\/wp\/v2\/categories?post=18602"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.cnbcsd.com\/fr\/wp-json\/wp\/v2\/tags?post=18602"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}