{"id":18635,"date":"2026-07-27T08:22:44","date_gmt":"2026-07-27T00:22:44","guid":{"rendered":"https:\/\/www.cnbcsd.com\/?p=18635"},"modified":"2026-07-27T10:40:09","modified_gmt":"2026-07-27T02:40:09","slug":"mns-low-voltage-withdrawable-switchgear","status":"publish","type":"post","link":"https:\/\/www.cnbcsd.com\/es\/mns-low-voltage-withdrawable-switchgear\/","title":{"rendered":"MNS Conmutaci\u00f3n extra\u00edble de baja tensi\u00f3n"},"content":{"rendered":"<p><strong>Descripci\u00f3n general<\/strong><\/p>\n<p>Esta serie de armarios de interruptores de baja tensi\u00f3n es adecuada para su uso en centrales el\u00e9ctricas, subestaciones, industrias petroqu\u00edmicas, metalurgia y laminado de acero, transporte y energ\u00eda, industria ligera y textiles, as\u00ed como comunidades residenciales y edificios de gran altura. lt est\u00e1 dise\u00f1ado para la conversi\u00f3n, distribuci\u00f3n y control de potencia en sistemas de alimentaci\u00f3n de CA con una frecuencia de 50-60 Hz y una tensi\u00f3n nominal de funcionamiento de 660 V o inferior. Este equipo cumple con las normas profesionales nacionales como GB7251.1 &#8220;Conjunto de equipos de interrupci\u00f3n de baja tensi\u00f3n&#8221; y JB \/ T9961 &#8220;Conjunto de equipos de interrupci\u00f3n de baja tensi\u00f3n&#8221;, as\u00ed como con las normas profesionales internacionales como lEC439-1 y VDE0660 Parte 5.<\/p>\n<p><strong>Modelo Significado<\/strong><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-18637\" src=\"https:\/\/www.cnbcsd.com\/wp-content\/uploads\/2026\/07\/MNS-Low-voltage-withdrawable-switchgear-Model.jpg\" alt=\"MNS Low-voltage withdrawable switchgear Model\" width=\"1468\" height=\"200\" srcset=\"https:\/\/www.cnbcsd.com\/wp-content\/uploads\/2026\/07\/MNS-Low-voltage-withdrawable-switchgear-Model.jpg 1468w, https:\/\/www.cnbcsd.com\/wp-content\/uploads\/2026\/07\/MNS-Low-voltage-withdrawable-switchgear-Model-768x105.jpg 768w\" sizes=\"auto, (max-width: 1468px) 100vw, 1468px\" \/><\/p>\n<p><strong>Condiciones de uso<\/strong><br \/>\n\u25aa La temperatura del aire ambiente no supera los +40\u00b0C y no cae por debajo de los -5\u00b0C, y la temperatura media durante un per\u00edodo de 24 horas no supera los +35\u00b0C;<br \/>\n\u25aa Condiciones atmosf\u00e9ricas: Aire limpio, humedad relativa no supera el 50% a una temperatura m\u00e1xima de +40&#8217;c. Se permite una humedad relativa m\u00e1s alta a temperaturas m\u00e1s bajas, por ejemplo, 90% a +20&#8217;c, pero los cambios de temperatura deben considerarse, ya que la condensaci\u00f3n puede ocurrir ocasionalmente;<br \/>\n\u25aa La altitud no supera los 2000 metros;<br \/>\n\u25aa Este dispositivo es adecuado para procesos de transporte y almacenamiento dentro del rango de temperatura de -25&#8217;c a +55&#8217;c. puede soportar temperaturas de hasta +70&#8217;c durante per\u00edodos cortos (no m\u00e1s de 24 horas, bajo estas temperaturas extremas, el dispositivo no debe sufrir ning\u00fan da\u00f1o irreversible y debe funcionar normalmente en condiciones normales;<br \/>\n\u25aa Si las condiciones de funcionamiento anteriores no se pueden cumplir, el usuario y el fabricante deben negociar una soluci\u00f3n;<br \/>\n\u25aa Cuando este dispositivo se utilice en plataformas de perforaci\u00f3n petrolera en alta mar o centrales nucleares, debe firmarse un acuerdo t\u00e9cnico separado.<\/p>\n<p><strong>Principales par\u00e1metros t\u00e9cnicos<\/strong><\/p>\n<p>&nbsp;<\/p>\n<table>\n<tbody>\n<tr class=\"firstRow\">\n<td colspan=\"2\" rowspan=\"1\">Item<\/td>\n<td>Argument<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" rowspan=\"1\">Rated insulation voltage<\/td>\n<td>660V(1000)V<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" rowspan=\"1\">Rated operating voltage<\/td>\n<td>380V\u3001660V<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" rowspan=\"1\">Maximum working current of main bus<\/td>\n<td>5000A<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" rowspan=\"1\">Rated withstand current of main bus<\/td>\n<td>100kA\/1s<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" rowspan=\"1\">Rated withstand current of main bus<\/td>\n<td>220kA\/0.1s<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" rowspan=\"1\">Maximum operating current of the distribution bus(vertical bus)<\/td>\n<td>1000A<\/td>\n<\/tr>\n<tr>\n<td colspan=\"1\" rowspan=\"2\">Distribution bus(vertical bus)peak current<\/td>\n<td colspan=\"1\" rowspan=\"1\">Normal Form10<\/td>\n<td>5kA(Max.)\/0.1s<\/td>\n<\/tr>\n<tr>\n<td colspan=\"1\" rowspan=\"1\">Enhanced 17<\/td>\n<td>6kA(Max.)\/0.1s<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><\/p>","protected":false},"excerpt":{"rendered":"<p>Descripci\u00f3n general Esta serie de armarios de interruptores de baja tensi\u00f3n es adecuada para su uso en centrales el\u00e9ctricas, subestaciones, industrias petroqu\u00edmicas, metalurgia y laminado de acero, transporte y energ\u00eda, industria ligera y textiles, as\u00ed como comunidades residenciales y edificios de gran altura. lt est\u00e1 dise\u00f1ado para la conversi\u00f3n, distribuci\u00f3n y control de potencia en [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":18636,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[136],"tags":[162],"class_list":["post-18635","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-smart-hv-lv-switchgear","tag-smart-hv-lv-switchgear"],"_links":{"self":[{"href":"https:\/\/www.cnbcsd.com\/es\/wp-json\/wp\/v2\/posts\/18635","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.cnbcsd.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.cnbcsd.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.cnbcsd.com\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.cnbcsd.com\/es\/wp-json\/wp\/v2\/comments?post=18635"}],"version-history":[{"count":2,"href":"https:\/\/www.cnbcsd.com\/es\/wp-json\/wp\/v2\/posts\/18635\/revisions"}],"predecessor-version":[{"id":18669,"href":"https:\/\/www.cnbcsd.com\/es\/wp-json\/wp\/v2\/posts\/18635\/revisions\/18669"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.cnbcsd.com\/es\/wp-json\/wp\/v2\/media\/18636"}],"wp:attachment":[{"href":"https:\/\/www.cnbcsd.com\/es\/wp-json\/wp\/v2\/media?parent=18635"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.cnbcsd.com\/es\/wp-json\/wp\/v2\/categories?post=18635"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.cnbcsd.com\/es\/wp-json\/wp\/v2\/tags?post=18635"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}